Automatic cold-chain control for businesses that store food and other cold-chain products · wireless sensors, pre-configured kit

Guide · updated October 2026

HACCP temperatures for fridges and cold rooms: the practical guide for anyone who stores food

Which temperatures to keep to, whether recording is mandatory, where to measure and what to do when a fridge goes out of range. Written for people who run a food business, not for technicians: restaurants, café-bars, bakeries, pastry shops, gelato shops, hotels, food shops.

In short. Temperatures must always be monitored. Recording is required ‘where necessary’ by Regulation (EC) No 852/2004, but in practice it is the simplest way to demonstrate that the cold chain was maintained. The values below are regulatory references: the thresholds that apply to you are the ones written in your self-monitoring plan.

According to the World Health Organization, around 600 million people worldwide fall ill every year from eating contaminated food. Temperature control along the cold chain is one of the simplest and most effective preventive measures.

What the law says

The European reference is Regulation (EC) No 852/2004 on the hygiene of foodstuffs. Among the requirements for premises (Annex II, Chapter I) it provides for adequate facilities to keep food at the right temperature and for temperature to be monitored and, where necessary, recorded.

The European Commission, in Communication 2022/C 355/01 on food safety management systems, describes automatic records as useful during storage and transport and notes that without records it is difficult to demonstrate compliance with good practice. For small businesses it allows simplifications, for example recording only non-conformities, but points out that maintaining the correct temperature matters more than writing it down.

Regulation (EC) No 853/2004, on the other hand, sets specific temperatures for certain foods of animal origin (meat, fishery products, milk), while in Italy many food hygiene services still refer to the values in Annex C of Presidential Decree D.P.R. 327/1980 and, for quick-frozen foods, to Legislative Decree D.Lgs. 110/1992.

Quick-frozen foods: the specific requirements of Regulation (EC) No 37/2005

For quick-frozen foods (those covered by Directive 89/108/EEC, transposed in Italy by Legislative Decree 110/1992) stricter rules apply, separate from the general obligations of Regulation (EC) No 852/2004. Regulation (EC) No 37/2005 requires that, during transport, warehousing and storage, the air temperature be monitored with suitable recording instruments, at regular and frequent intervals. The instruments must comply with EN 12830 (temperature recorders), EN 13485 (thermometers) and EN 13486 (periodic verification). Records must be dated and kept by the operator for at least one year, or longer depending on the nature and shelf life of the product.

The regulation provides for exemptions: in retail display cabinets and refrigerated cabinets, and in local distribution, at least one easily visible thermometer is sufficient (in open cabinets, placed on the air-return side at the load line); Member States may also allow a visible thermometer alone for cold rooms with a capacity below 10 m³ in retail outlets.

Gelato is not a quick-frozen food. Directive 89/108/EEC expressly excludes ice cream – gelato included – from its scope: for display cases and storage freezers in gelato shops, the requirements of Regulation (EC) No 37/2005 do not apply automatically; the self-monitoring plan and the reference values of D.P.R. 327/1980 still apply. If your business also stores quick-frozen products (bases, semi-finished goods, packaged products), the assessment must be made product by product, with your consultant.

In summary: automatic monitoring is not mandatory for everyone. Regulation (EC) No 852/2004 requires monitoring and recording ‘where necessary’ according to the self-monitoring plan; Regulation (EC) No 37/2005 imposes compliant recording instruments only for quick-frozen foods and outside the exemptions. Applicability depends on products, processes and the self-monitoring plan. A service like KRYO helps you meet temperature monitoring and recording obligations with measurements at regular intervals and verifiable records; overall compliance of the HACCP plan remains the business’s responsibility, and the instruments’ compliance with the technical standards must be documented case by case.

Reference temperature table

FoodTemperatureReference
Minced meat≤ +2 °CReg. (EC) No 853/2004
Offal≤ +3 °CReg. (EC) No 853/2004
Poultry and rabbit≤ +4 °CReg. (EC) No 853/2004
Fresh meat≤ +7 °CReg. (EC) No 853/2004
Fresh fishery productsclose to 0 °C (melting ice)Reg. (EC) No 853/2004
Pasteurised milk, yoghurt and fermented milks≤ +4 °CD.P.R. 327/1980
Fruit gelato≤ −10 °C (tolerance +3 °C)D.P.R. 327/1980, Annex C
Other gelato≤ −15 °C (tolerance +3 °C)D.P.R. 327/1980, Annex C
Quick-frozen foods≤ −18 °C (brief fluctuations up to +3 °C)D.Lgs. 110/1992
Frozen meat and fishery products≤ −18 °CReg. (EC) No 853/2004
Cooked dishes to be eaten cold≤ +10 °CD.P.R. 327/1980, Art. 31
Cooked dishes to be eaten hot+60 / +65 °CD.P.R. 327/1980, Art. 31

Source of the summary: SIAN – AULSS 9 Scaligera, ‘Temperatura di conservazione’ (storage temperature). Tolerances refer to brief temperature rises during distribution. Always check the values on the label and in your self-monitoring plan.

Where to measure the temperature

  • Not near the door: it is the spot that warms up at every opening and reads warmer than the stock actually is.
  • Not against the evaporator: the air there is colder than the stock, so readings come out colder than the stock actually is.
  • In the area where the stock sits, at mid-height, where the temperature represents that of the product.
  • In display cases, in the display area, not in the technical compartment.

How often to check

With a manual log, checks are usually made once or twice a day, at opening and closing. The limitation is obvious: a problem that starts after closing is discovered only the next day. An automatic system reads the temperature at regular intervals, at night and on closing days too, and alerts you when a value stays out of range for several consecutive readings: not instantly, but while the problem is still happening.

What to do if a fridge is out of range

  1. Check the simplest cause: door open or not shut properly, overloading, defrost cycle in progress.
  2. Work out how long the temperature has been out of range and by how much: this is the information that decides the fate of the stock.
  3. Move the stock to another fridge if the problem is not resolved quickly.
  4. Decide on the stock according to the procedures in your self-monitoring plan, with your consultant if needed.
  5. Record the non-conformity and the corrective action: what happened, what you did, who intervened.
  6. Contact the maintenance technician if the fault concerns the unit.
Point 2 is the one the paper log cannot tell you: if you read 3 °C at 23:00 and 10 °C at 08:00, you do not know whether the temperature rose at 23:30 or at 07:30. With continuous recording you know to the minute.

Manual or automatic log?

A paper log is permitted, but it has three limitations: it depends on the memory of whoever fills it in, it captures only a few moments of the day and it does not alert you. An automatic system like KRYO records at regular intervals, keeps the history of every fridge, produces a daily verdict for each cold room and sends you an alert when action is needed. Your consultant can specify it in the self-monitoring plan as the monitoring method for temperature-related points.

Understanding monitoring: six questions that make the difference

Before choosing a tool, it is worth being clear about what it measures, when it alerts and what remains with the people doing the work. The answers below describe how KRYO behaves as configured and documented.

Thermometer, data logger or remote monitoring: what is the difference?
A thermometer shows the current value to whoever looks at it: it has to be read and written down. A data logger saves readings at intervals, but the data is only seen when someone downloads it: useful for reconstructing events, not for acting on them. Remote monitoring transmits the readings to a service that compares them with the thresholds and alerts the right people while the problem is happening, keeping the history. KRYO normally reads and transmits every 3–5 minutes: it is periodic monitoring, not an instantaneous measurement, and the temperature alert is sent after at least two consecutive out-of-range readings.
Cold room air temperature or food temperature?
The cold room sensor measures the air where it is placed, not the core of the product. Food has more thermal inertia: a brief door opening raises the air temperature by a few degrees without affecting it, while a long excursion compromises it even after the temperature recovers. That is why the duration and extent of excursions matter, not a single peak, and why the sensor should be placed close to the stock and away from the cold air outlet. Core temperature remains a probe measurement where the self-monitoring plan requires it, for example during blast chilling.
Why monitor door openings?
The door is the leading cause of avoidable excursions: long openings during loading, doors left open, seals that no longer hold. With a door sensor you see when and for how long each cold room is opened and receive an alert if it stays open longer than the configured time, before the temperature leaves the limits. Read alongside the temperature, the opening history tells you whether an excursion is down to working practices or to the unit.
How should a cold room’s electrical consumption be read?
As a trend over time, not as a bill: how much the cold room draws, how long it runs, how it changes compared with previous weeks, what it consumes with the doors closed. A unit that runs longer at the same temperature and with the same number of door openings is something to raise with whoever does the maintenance. KRYO makes temperature, door and energy data visible on the same timeline; interpreting the cause remains with whoever intervenes.
What happens if the internet or the power goes down?
The service notices that the central unit is no longer reachable and sends an alert; in the log the period appears as incomplete monitoring, never as ‘All clear’. The battery-powered sensors keep measuring and store the readings locally, as does the central unit; automatic recovery of those readings into the log once power and connectivity are back is confirmed in the proposal. During a blackout the refrigeration units are down too: the alert is the signal to intervene.
Who manages the alerts and who is responsible for intervening?
Alerts reach the recipients designated for each point via Telegram and email, with what to check; WhatsApp support is coming. Intervening remains the job of whoever receives the alert: KRYO measures and alerts, it does not act on the units and is not an emergency call-out service. It is worth defining in the self-monitoring plan who receives what, at what times, and what to do in each case; escalation to a second contact when nobody takes charge is provided for and is confirmed in the proposal.

Frequently asked questions

Is HACCP temperature recording mandatory?
Regulation (EC) No 852/2004 requires temperature to be monitored and recorded ‘where necessary’, according to the self-monitoring plan. Simplifications are allowed for small businesses, but without records it is hard to demonstrate that the cold chain was maintained.
What temperature should a restaurant fridge be kept at?
It depends on what it holds. As a reference: minced meat up to +2 °C, poultry up to +4 °C, fresh meat up to +7 °C, pasteurised milk up to +4 °C, quick-frozen foods at −18 °C or below. The exact thresholds are those in your self-monitoring plan.
At what temperature should gelato be stored?
As a reference, Italian Presidential Decree D.P.R. 327/1980 specifies −15 °C for gelato and −10 °C for fruit gelato, with a tolerance of +3 °C for short periods. Serving temperature in the display case depends on the product.
How long must the temperature log be kept?
For quick-frozen foods, Regulation (EC) No 37/2005 requires at least one year, or longer depending on the product’s shelf life. For everything else, European legislation does not set a single period: your self-monitoring plan sets it, usually linking it to the shelf life of the products. Ask your HACCP consultant to confirm.
Is automatic temperature monitoring mandatory?
No, not for everyone. It is mandatory, in the form of recording instruments compliant with the technical standards, for quick-frozen foods outside the exemptions of Regulation (EC) No 37/2005. In all other cases Regulation (EC) No 852/2004 requires monitoring and recording ‘where necessary’, according to the self-monitoring plan: automatic monitoring is a choice that simplifies the obligation and makes it demonstrable.

Sources

This guide is for information purposes and does not replace the self-monitoring plan or the advice of your HACCP consultant or the health authority.

Want to stop filling in the log by hand?

KRYO monitors and records temperatures for you and alerts you while the problem is happening, so you can act in time and reduce the risk of loss.

Assess monitoring for your cold rooms
Assess monitoring for your cold rooms