KRYO sensors
Wireless temperature and humidity sensors for HACCP
Periodic readings, 24 hours a day. An alert when a value stays out of range. Automatic log.
Wireless, battery-powered sensors for chilled and frozen cold rooms, fridges, freezers and display cases. They do not use the Wi-Fi on your premises, need no building work and arrive pre-configured. Choosing the components is part of the service: they are professional CE-marked devices, configured by KRYO.
The cold room sensor: temperature and humidity
Temperature
From −30 °C to +70 °C.
Typical accuracy declared by the manufacturer: ±0.3 °C from 0 to +70 °C and ±0.6 °C from −30 to 0 °C; resolution 0.1 °C. Chilled and frozen cold rooms, fridges, freezers, display cases, blast chillers in the holding phase (not during the blast-chilling cycle). Every reading is recorded and compared with the thresholds in your HACCP self-monitoring plan.
Relative humidity
From 0 to 100 %, in non-condensing conditions.
Typical accuracy ±3 % between 10 and 90 % RH (±5 % at the extremes), at 25 °C. The same sensor measures the humidity of the compartment: useful for cold rooms, the production room and dry storage. The values given apply to this sensor; other KRYO components have their own specifications.
Measure, transmit, alert
Three distinct timings, stated openly.
The sensor reads and transmits at regular intervals, normally every 3–5 minutes (configurable). KRYO compares each reading with the thresholds; a temperature alert goes out after at least two consecutive out-of-range readings, so roughly 6–10 minutes from the start of the anomaly with the typical interval, plus message delivery time. This is what “continuous” means, not instant transmission.
A silent sensor does not go unnoticed
Silence is not “all clear”.
If a sensor or the central unit stops transmitting for longer than the time limit, the service detects it and reports it to you and to KRYO support. The interval with no readings stays recorded in the log. We propose where each sensor goes from your photos, close to the stock and away from the cold air outlet, and confirm it at activation.
The other sensors in the service
On the same central unit, with the same alerts and the same history: door, energy and production room are read alongside the cold room temperature.
Power meters
Per unit or at the electrical panel, with single-phase or three-phase supply. They make the consumption trend and running times of each cold room visible, to be read alongside the temperature. Details
Door sensors
On the door of each cold room: they record openings and closings with time and duration and trigger an alert if the door stays open longer than the time you configure with us; there is no preset threshold.
Room sensor
For the production room and ambient-temperature areas: temperature and relative humidity, with thresholds from your self-monitoring plan, in the same history as the cold rooms. It is not a microbiological check.
Why KRYO sensors do not use Wi-Fi
A connection that drops is not a control system.
Dedicated radio
The sensors communicate over radio with the central unit on a long-range, low-power band, generally better suited than Wi-Fi to cold room walls and doors. Actual coverage depends on materials and distances: we estimate it from your photos and verify it at activation, sensor by sensor.
Central unit by cable
The central unit connects to the router with a network cable, no SIM: no dependence on Wi-Fi coverage in the back room or the production room.
Remote checks
We check remotely that every sensor is transmitting. If a sensor stops communicating, you know, and so do we.
Key specifications
| Quantities measured by the cold room sensor | Temperature from −30 °C to +70 °C (typical accuracy ±0.3 °C from 0 to +70 °C, ±0.6 °C from −30 to 0 °C); relative humidity from 0 to 100 %, non-condensing (±3 % between 10 and 90 %) |
| Readings and alerts | Reading and transmission normally every 3–5 minutes (configurable); temperature alert after at least two consecutive out-of-range readings |
| Standards | Cold room sensor declared by the manufacturer to comply with EN 12830; compliance of the whole recording chain (sensor, transmission, archive) is documented case by case with your consultant |
| Applications | Chilled and frozen cold rooms, fridges, freezers, display cases, blast chillers in the holding phase, production room and storeroom |
| Connection | Radio, wireless, to the central unit; coverage verified at activation |
| Power supply | Battery; the level is monitored by the service |
| Installation | No building work and no intervention on the refrigeration units |
| Configuration | Carried out by KRYO before shipping, based on your photos; position and coverage confirmed at activation |
| Central unit | Connected to the router with a network cable (Ethernet), no SIM |
| Alerts | Telegram and email (WhatsApp coming soon) · three states: All clear, Attention, Action required |
| HACCP log | Automatic recording of every reading, daily verdict per cold room, PDF report with integrity fingerprint (SHA-256) kept in the log |
| Other areas | Door sensors, single-phase and three-phase power meters, room sensor (temperature and humidity), label printer: activated with the configuration agreed in the proposal |
Measuring range and accuracy are those declared by the manufacturer for the KRYO cold room sensor in the version supplied; battery life depends on the transmission interval and on temperature and is stated in the proposal. Other components have their own specifications.
Where the sensors go
- Cold rooms
- Frozen cold rooms
- Fridges
- Freezers
- Refrigerated display cases
- Refrigerated counters
- Blast chillers (holding phase)
- Gelato storage freezers
- Proving chambers
- Production room
- Storeroom
The exact point matters: away from the door and the evaporator, in the zone where the stock sits. We propose it, sensor by sensor, from your photos, and confirm it at activation together with the radio coverage. Read more in the HACCP temperature guide.
Frequently asked questions about wireless sensors
What is the difference between a data logger and a KRYO wireless sensor?
Do the sensors need Wi-Fi to work?
Can they go inside a frozen cold room or a blast chiller?
Does the instrument comply with EN 12830, required for frozen foods?
What happens if a sensor stops transmitting?
Can I add sensors later?
How many sensors does your business need?
Send us a few photos of your cold rooms, fridges and display cases: we’ll tell you how many sensors you need and where.