Automatic cold-chain control for businesses that store food and other cold-chain products · wireless sensors, pre-configured kit

For HACCP consultants and food technologists

Temperature monitoring for HACCP consultants

Temperatures measured, not declared.

The self-monitoring plan you write is only as sound as the data behind it. KRYO gives the businesses you look after temperature readings at regular intervals, with a log nobody has to fill in by hand.

What changes for the HACCP consultant

Continuous data

Not two readings a day written down at the end of the shift, but continuous recording for every cold room, fridge and display case.

Documented non-conformities

Every threshold breach has a date, time and duration. Corrective actions are assessed on measured facts.

More reliable clients

Businesses receive the alert while the problem is happening and can act in time, reducing the risk of loss. The log can be exported to PDF per cold room and period, with an integrity fingerprint (SHA-256) kept in the log.

No overlap with your work

KRYO does not sell HACCP consultancy, does not write manuals and does not offer training courses. We measure and alert: hazard analysis, critical limits and corrective actions remain your responsibility.

Alarm thresholds are set according to the self-monitoring plan you have drawn up for each client.

Where KRYO supports self-monitoring

  • Monitoring of temperature-related control points
  • Continuous recording of storage temperatures
  • Detection of sensors that stop transmitting
  • Evidence of non-conformities and time taken to return within range
  • Daily verdict per cold room: compliant, compliant with remarks, non-compliant, incomplete monitoring
  • Door openings, electrical consumption (single-phase and three-phase) and production-room climate (temperature and humidity), in the same history

Questions from HACCP consultants

Does KRYO replace the temperature log required by the self-monitoring plan?
KRYO replaces manual temperature entries with automatic, continuous recording. It is up to the consultant to state the monitoring method adopted in the self-monitoring plan.
Can alarm thresholds be customised?
Yes. Thresholds are set for each control point according to the limits defined in the client’s self-monitoring plan.
Does KRYO declare EN 12830 compliance for quick-frozen foods?
No, not automatically. Where Regulation (EC) No 37/2005 applies, the recording instrument’s compliance with EN 12830, EN 13485 and EN 13486 must be documented: we check this case by case during the analysis, together with you. For gelato, which is excluded from quick-frozen food legislation, the reference remains the self-monitoring plan.
How can I propose KRYO to my clients?
Write to us: together we assess the businesses you look after and their monitoring needs.

Are you a HACCP consultant?

Let’s talk about how measured data can strengthen your clients’ self-monitoring.

Start a conversation
Assess monitoring for your cold rooms