Automatic cold-chain control for businesses that store food and other cold-chain products · wireless sensors, pre-configured kit

For bakeries and food production labs

Cold room, proofing and production room monitoring for bakeries and food production labs

Doughs, fillings and semi-finished products protected in the hours when the production room is empty.

In a bakery, production starts at night and the most delicate stock sits in the cold room and the proofing chamber when nobody is watching. KRYO reads the temperature and humidity of cold rooms, cabinets and proofing chambers every 3–5 minutes, monitors the temperature and humidity of the production room, sends Telegram and email alerts to whoever can act, and keeps the history for the HACCP log.

No commitment · All we need is your type of business, number of cold rooms, main requirement and your contact details

Where problems happen in a bakery or food lab

The proofing chamber

Too warm or too cold for a few hours and the morning’s dough is not what you planned. The right value depends on the recipe: KRYO checks that it stays within the range you set, humidity included.

The production room in summer

Ovens running and 30 °C in the production room change working times and how well creams and fillings hold. Room temperature and humidity go into the same history as the cold rooms.

Afternoons and Sundays

After the morning’s sales the production room empties: cabinets full of fillings, creams and semi-finished products are left unwatched until the following night.

What KRYO monitors in your production room

  • Chilled and frozen cold rooms for raw materials, semi-finished and finished products
  • Refrigerated cabinets for doughs, creams, fillings and deli products
  • Proofing chambers: temperature and humidity within your recipe’s range
  • Blast chiller, in holding mode
  • Production room and dry store: temperature and humidity of the working environment
  • Cold room doors: openings recorded, alert if left open beyond the configured time
  • Electrical consumption of cold rooms and cabinets (single-phase and three-phase), as a trend to read with your maintenance contractor
  • Expiry-date labels for semi-finished products and preparations, with an inventory for each cold room

With the free assessment we identify the critical points together: in a bakery there are often three or four, not ten.

Most common reference temperatures

Creams, fillings and egg-based products≤ +4 °C
Milk, cream, butter≤ +4 °C
Doughs in refrigerated storageas per recipe and self-monitoring plan
Frozen semi-finished products≤ −18 °C
Proofing chamberrecipe range (temperature and humidity)

Indicative values; the thresholds to apply are those of your self-monitoring plan and your recipes. HACCP temperature guide

Three typical situations, from event to action

Illustrative examples with sample values.

Proofing · 23:10

Proofing chamber below range

Detected: 21 °C for two consecutive readings, set range 26–28 °C. Alert: to the production manager, before the night shift arrives. Check: in the history the drop starts at 22:40, coinciding with a recorded door opening. Action: whoever arrives first checks the door and the unit; the dough can still be dealt with.

Production room · 15:30

Production room temperature above threshold

Detected: 27 °C and 70 % humidity, plan thresholds 25 °C / 65 %. Alert: to the production room manager. Check: the history shows the rise has repeated every afternoon for a week. Action: review air conditioning and the timing of the most delicate work; the data stays on record in support of the self-monitoring plan.

Fillings cabinet · Sunday

Refrigerated cabinet stopped with the production room closed

Detected: temperature rising steadily since 14:00, with no recovery. Alert: Attention first, then Action required, to the owner and the manager. Check: electrical consumption at zero since the same time. Action: move creams and fillings to another cold room and call the technician on Monday, with the data to hand.

HACCP log and proofing in the same history

The cold room temperature log fills itself in, with a verdict for every cold room and every day, and can be exported as a PDF with an integrity fingerprint for your consultant or an inspection. The proofing chamber and the production room environment are not strictly HACCP points for everyone, but they sit in the same history: you need them for product quality and to understand what happened when something is not right.

KRYO helps you meet the temperature monitoring and recording obligations that apply to your business, within your self-monitoring plan; the plan, the critical limits and the corrective actions remain yours and your consultant’s.

Questions from bakers and production room managers

Can the sensor cope inside a hot, humid proofing chamber?
The cold room sensor operates from −30 °C to +70 °C and from 0 to 100 % relative humidity in non-condensing conditions. Humidity is high during proofing: the mounting point is chosen to avoid direct condensation on the sensor, and we confirm it at activation.
Can I set a range, not just a maximum threshold?
Yes: for every point you set a minimum and a maximum threshold and a delay time. For proofing, the range is the one in your recipe.
The production room is separate from the shop: does the radio reach?
Usually yes: the sensors use a long-range, low-power radio link to the central unit, better suited to walls and doors than Wi-Fi. Actual coverage depends on materials and distances: we estimate it from the photos and confirm it at activation, moving the sensor or the central unit if needed.
We work at night: do the alerts reach whoever is in the production room?
Yes. You set recipients by time slot or by point, for example the night supervisor for the production cold rooms and the owner for everything. Alerts arrive on Telegram and email; WhatsApp support is coming.
Do I need a technician in the production room to install it?
For the temperature kit, in most cases no: it arrives pre-configured, you connect the central unit to the router with a network cable and place the sensors. Only the power meters at the electrical panel require qualified personnel.

Cold rooms, proofing and production room in one history.

Tell us your type of business, number of cold rooms and main requirement: we tell you where to start.

Assess monitoring for your cold rooms
Assess monitoring for your cold rooms