Automatic cold-chain control for businesses that store food and other cold-chain products · wireless sensors, pre-configured kit

For restaurants, café-bars and hotels

Cold room and fridge monitoring for restaurants, café-bars and hotels

Your kitchen’s cold chain, watched over even when the kitchen is closed.

Meat, fish, preparations for the next service, milk and cream at the counter, the hotel breakfast: a cold room holds thousands of euros and hours of work. KRYO reads temperature and humidity every 3–5 minutes, flags the anomaly while it is happening, not when you open up the next day, and keeps the history for the HACCP log. Whoever is on shift receives the alert and can act.

No commitment · All we need is your type of business, number of cold rooms, main requirement and your contact details

Where problems happen in the kitchen, at the counter and in hotels

After service

You close late, the cold room door is left ajar, nobody notices until morning. With the door sensor the alert goes out when the door stays open beyond the set time, before the temperature rises.

Closing day and hotel nights

A whole day with nobody in the kitchen; in a hotel the kitchen closes but the cold rooms stay stocked for breakfast. A Monday-morning fault only comes to light on Tuesday, if nobody flags it.

During service and at the counter

Line fridges and café-bar counters are opened constantly. Nobody has time to watch the thermometers; brief openings should not trigger alerts, long temperature excursions should.

What KRYO monitors in a restaurant, a café-bar and a hotel

  • Cold rooms for meat, fish, vegetables and dairy; frozen cold rooms and freezers
  • Line fridges and refrigerated prep counters in the kitchen
  • Counters and display cases at the café-bar: milk, cream, sandwiches, pastries, fresh products on display
  • Blast chiller, in holding mode
  • Cold room doors: openings recorded with time and duration, alert if left open beyond the configured time
  • Electrical consumption per cold room or at the panel (single-phase and three-phase), as a trend to read with your maintenance contractor
  • Several kitchens or multiple sites: one service, recipients per department, the same history

With the free assessment we establish together which points are truly critical. There is no need for a sensor everywhere.

Most common reference temperatures

Minced meat≤ +2 °C
Poultry and rabbit≤ +4 °C
Fresh meat≤ +7 °C
Pasteurised milk and cream≤ +4 °C
Fresh fishery productsclose to 0 °C (melting ice)
Quick-frozen and frozen foods≤ −18 °C

Reference values from Regulation (EC) No 853/2004 and Italian Legislative Decree 110/1992. The thresholds to apply are those of your self-monitoring plan. Full guide

Three typical situations, from event to action

Illustrative examples with sample values.

Restaurant · 02:20

Meat cold room above threshold with the kitchen closed

Detected: +5.8 °C for two consecutive readings. Alert: to the owner, then ‘Action required’ to the chef if it continues. Check: the history shows the door open since 01:50. Action: whoever is closest goes in to close it; the non-conformity stays on record with start, end and duration.

Café-bar · 07:40

Counter opened constantly at peak time

Detected: frequent openings, temperature recovering within the delay time. Alert: none. Check: at the end of the day the history shows the normal fluctuations of service. Action: none; the log is complete without a single hand-filled sheet.

Hotel · two kitchens

Breakfast and restaurant cold rooms, different shifts

Detected: breakfast cold room out of range overnight. Alert: to the night duty manager, not to the chef at home. Check: electrical trend and door openings of the same cold room on the same timeline. Action: move the stock to the restaurant cold room and have the unit checked in the morning.

HACCP log without end-of-shift sheets

At the end of service, with a kitchen to clean, filling in the temperature sheet is the last thing on anyone’s mind. And it is precisely the sheet written in a hurry, or from memory, that fails to protect you during an inspection.

With KRYO every fridge has an automatic history of periodic readings, with a verdict for every day. In an inspection you show the actual temperatures of every day, including the moments when there was a problem, and the log exports as a PDF with an integrity fingerprint. That is how KRYO helps you meet the monitoring and recording obligations of Regulation (EC) No 852/2004, within your self-monitoring plan: the plan remains yours.

Questions from restaurateurs, café-bar and hotel owners

Do I get an alert every time I open the cold room or the counter?
No. A temperature alert goes out after at least two consecutive readings out of range, so brief openings during service do not trigger it. With the door sensor, the dedicated alert goes out only if the door stays open beyond the time you set with us.
I run a pizzeria with two fridges, or a café-bar with a counter and a fridge. Is it for me too?
Yes. Even two fridges full of mozzarella and dough, or the café-bar counter with milk and cream, are worth a day’s work. The service is sized on the points you actually have.
In a hotel I have several kitchens and shifts: who receives the alerts?
You set recipients for each point or department, for example the night duty manager for the breakfast cold rooms and the chef for the restaurant ones. All points sit in the same history.
Who receives the alerts when I’m on holiday?
You can name one or more people: for example you and your head of kitchen. Acting on the alert is up to whoever receives it: KRYO does not operate the units.
Does consumption data tell me if a fridge is about to fail?
It shows you whether a unit is running longer or drawing more than in previous weeks, at the same temperature. It is something to put to your maintenance contractor, not a diagnosis: the technician establishes the cause.

What is the stock in your cold rooms worth tonight?

Tell us your type of business, number of cold rooms and main requirement: we tell you how to protect them.

Assess monitoring for your cold rooms
Assess monitoring for your cold rooms